Lintel Design in London

Every new opening in a masonry wall — a window, a door, a bifold — needs a lintel to carry the brickwork above. Lintel design selects the right lintel type and size for the wall construction, the span and the load, with the bearings and details the builder needs.

Steel beam installed across a new opening between a kitchen and dining room

Scope of work

  • Assessment of the load above the opening
  • Selection of lintel type — steel, prestressed concrete or combined
  • Bearing lengths and support details
  • Details for cavity, solid and timber-frame walls
  • Calculations for building control where required

Typical applications

  • New windows and doors in existing walls
  • Enlarged openings for bifold or sliding doors
  • Replacement of failed or undersized lintels
  • Openings in extension walls

Our design process

  1. 1

    Initial enquiry

    Tell us about your project through the contact form, including any drawings or photographs you already have.

  2. 2

    Review of information

    We review the available information — existing drawings, architectural proposals, site measurements and photographs — and confirm what is needed.

  3. 3

    Quotation

    We agree the scope and fee with you before any design work begins, so you know exactly what will be provided.

  4. 4

    Design and checking

    We carry out the agreed calculations, drawings or specifications, checked against the relevant standards.

  5. 5

    Issue of deliverables

    The agreed drawings, calculations or design notes are issued to you electronically, ready for your builder or building control.

Information we will need

  • The width and position of the proposed opening
  • Wall construction — cavity or solid, and approximate thickness
  • What is above the opening — roof, floor, or more wall
  • Photographs of the wall inside and out

Deliverables

  • Lintel specification for each opening
  • Bearing and installation details
  • Calculations where the loading is beyond standard tables

Limitations and approvals

Many standard lintels are selected from manufacturers' tables; calculations are provided where the loading is unusual or the span is large. Lintel design is engineering work — installation is carried out by your builder, and building control approval is a separate process.

Frequently asked questions

My lintel has cracked — does it need replacing?
Not always. Some cracks are cosmetic; others indicate the lintel is failing. Send photographs and we can advise whether investigation or replacement design is needed.
Can one lintel span a wide bifold opening?
Wide openings usually need a designed steel beam rather than a standard lintel — our beam design service covers that.
Do new windows need building control approval?
Replacement windows are usually covered by the installer's competent person scheme, but creating or enlarging an opening is structural work that building control should approve.

Related services

Ready to talk about your project?

Tell us what you need and we'll come back to you about a quotation.